Difference between revisions of "6502 Instructions - Introduction"

From CDOT Wiki
Jump to: navigation, search
(Undo revision 157525 by Chris Tyler (talk))
Line 3: Line 3:
 
The [[6502]] processor has a compact instruction set, consisting of just 56 instructions:
 
The [[6502]] processor has a compact instruction set, consisting of just 56 instructions:
  
ADC AND ASL BCC BCS BEQ BIT BMI BNE BPL BRK BVC BVS CLC
+
<code>
  CLD CLI CLV CMP CPX CPY DEC DEX DEY EOR INC INX INY JMP
+
ADC AND ASL BCC BCS BEQ BIT BMI BNE BPL BRK BVC BVS CLC
  JSR LDA LDX LDY LSR NOP ORA PHA PHP PLA PLP ROL ROR RTI
+
   
  RTS SBC SEC SED SEI STA STX STY TAX TAY TSX TXA TXS TYA
+
CLD CLI CLV CMP CPX CPY DEC DEX DEY EOR INC INX INY JMP
 +
   
 +
JSR LDA LDX LDY LSR NOP ORA PHA PHP PLA PLP ROL ROR RTI
 +
 +
RTS SBC SEC SED SEI STA STX STY TAX TAY TSX TXA TXS TYA
 +
</code>
  
 
This page groups these instructions and explains their basic function.
 
This page groups these instructions and explains their basic function.

Revision as of 12:41, 19 January 2022

Important.png
This is a draft only!
It is still under construction and content may change. Do not rely on this information.

The 6502 processor has a compact instruction set, consisting of just 56 instructions:

ADC AND ASL BCC BCS BEQ BIT BMI BNE BPL BRK BVC BVS CLC

CLD CLI CLV CMP CPX CPY DEC DEX DEY EOR INC INX INY JMP

JSR LDA LDX LDY LSR NOP ORA PHA PHP PLA PLP ROL ROR RTI

RTS SBC SEC SED SEI STA STX STY TAX TAY TSX TXA TXS TYA

This page groups these instructions and explains their basic function.


Addressing Modes

There are 13 6502 Addressing Modes. All of these instructions work with at least one addressing mode, and many work with several addressing modes. See the Resources section for Opcode tables that define which instructions work with which addressing modes.

Performance

Each 6502 instruction takes a defined number of machine cycles to execute. In some cases,the number of cycles will vary depending on the circumstances of the instruction's execution - for example, the conditional branch instruction BRE (Branch if EQual) takes:

  • 2 cycles if the branch is not taken
  • 3 cycles if a branch is taken to an address in the same page
  • 4 cycles if a branch is taken to an address in another page

Remember that the Program Counter (PC register) contains a pointer to the next instruction to be executed. When the BEQ instruction has been loaded into the CPU, the PC points to the instruction following the BEQ. The branch works by adding a signed integer value (in the range of -128 to +127) to the Program Counter; the extra cycle required when the branch is taken is used to process the addition. If the high byte of the Program Counter changes (because the branch crosses in to another page), one additional cycle is required to adjust the high byte.

You can find the execution time in the instruction charts found in the Resources section below.

To convert the number of cycles to time, multiply the cycles by the time between system clock pulses. Many 6502 systems operated at 1 MHz (1 million operations per second), and therefore 1 cycle corresponded to 1 millionth of a second, or 1 microsecond (uS). Therefore, an instruction that took 4 clock cycles would take 4 uS to execute.

Loading and Storing Data (to/from Memory)

Register-Memory Loads and Stores

There are three instructions to load data from memory to a register:

LDA ; load the accumulator
LDX ; load the X register 
LDY ; load the Y register

And there are three matching instructions to store data from a register to a memory location:

STA ; store the accumulator 
STX ; store the X register 
STY ; store the Y register

Push/Pull on the Stack

When a value is pushed to the stack, the stack pointer register (SP) is decremented and the selected register is written to memory location $0100+SP.

When a value is pulled from the stack, the stack pointer register (SP) is incremented and the selected register is loaded from memory location $0100+SP.

There are two instructions to push data onto the stack:

PHA ; push the accumulator
PHP ; push the processor status register

And two matching instructions to pull data from the stack:

PLA ; pull the accumulator
PLP ; pull the processor status register

Note that some other operations, such as JSR, interrupts, RTI, and RTS, cause data to be pushed to or pulled from the stack.

Arithmetic and Bitwise Operations

The 6502 has rudimentry addition and subtraction instructions:

ADC ; add with carry
SBC  ; subtract with carry

It also has instructions for left and right bit-shifts and rotations (which can act as multiply-by-2 and divide-by-2):

ASL ; arithmetic shift left
ROL ; rotate left

LSR ; logical shift right
ROR ; rotate right

There are also instructions for bitwise operations such as exclusive-OR, OR, and AND. Exclusive-OR with #$FF is equivalent to a NOT operation, and these operations can be combined to produce other logical operations such as NOR and NAND.

AND ; bitwise AND (with accumulator)
EOR ; bitwise exclusive-OR (with accumulator)
ORA ; bitwise OR (with accumulator)

For full details on these instructions, see the 6502 Math page.

Test and Comparison Operations

The A, X, and Y registers can be directly compared with immediate or memory values:

CMP ; compare (accumulator)
CPX ; compare (X register)
CPY ; compare (Y register)

These operations are performed by subtraction. The appropriate condition flags are set, and the result of the subtraction is discarded. Conditional branch instructions can be used to alter program flow based on the results of the comparisons.

There is another test instruction available:

BIT ; bit test

This instruction places bit 7 of the operand into the N flag and bit 6 of the operand into the V flag. The operand is then ANDed with the accumulator, and the Z flag is set if the result is zero. The result of the AND is discarded. In this way, you can test the value of bit 7, bit 6, or any arbitrary bits (using the operand).

Note that in addition to these instructions, many other instructions (such as register loads) affect condition flags.

Idea.png
Watch the Carry Flag!
Failing to clear the carry flag before addition or to set the carry flag before subtraction is the cause of many bugs in 6502 programs. The carry flag also affects the rotate instructions. Be sure to set or clear this flag with the SEC or CLC instructions when needed!